Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Ann Card Anaesth ; 26(1): 78-82, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36722592

RESUMO

Concomitant mitral and aortic valve stenosis in a patient with mitral annular calcification and porcelain aorta poses a unique problem to the surgical team. Transcatheter aortic and mitral valve replacements in native valves offer a viable option for such selected group of patients. We present the case of a 54-year-old male who presented with severe aortic stenosis (AS) and severe mitral stenosis (MS) but was deemed high risk for surgery owing to intense calcification of the aorta and mitral annular calcification, and successfully underwent transcatheter double native valve replacement.


Assuntos
Estenose da Valva Aórtica , Calcinose , Procedimentos Cirúrgicos Cardíacos , Estenose da Valva Mitral , Masculino , Humanos , Pessoa de Meia-Idade , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Calcinose/complicações , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
3.
Indian Heart J ; 73(3): 301-306, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34154746

RESUMO

INTRODUCTION: Transcatheter aortic valve replacement (TAVR) increases worldwide, and indications expand from high-risk aortic stenosis patients to low-risk aortic stenosis. Studies have shown that minimalistic TAVR done under conscious sedation is safe and effective. We report single-operator, the single-center outcome of 105 minimalist transfemoral, conscious sedation TAVR patients, analyzed retrospectively. METHODS: All patients underwent TAVR in cardiac catheterization lab via percutaneous transfemoral, conscious sedation approach. A dedicated cardiac anesthetist team delivered the conscious sedation with a standard protocol described in the main text. The outcomes were analyzed as per VARC-2 criteria and compared with the latest low-risk TAVR trials. RESULTS: A total of 105 patients underwent transcatheter aortic valve replacement between July 2016 to February 2020. The mean age of the population was 73 years, and the mean STS score was 3.99 ± 2.59. All patients underwent a percutaneous transfemoral approach. Self-expanding valve was used in 40% of cases and balloon-expandable valve in 60% (Sapien3™ in 31% and MyVal™ in 29%) of cases. One patient required conversion to surgical aortic valve replacement. The success rate was 99 percent. The outcomes were: all-cause mortality: 0.9%, stroke rate 1.9%, New pacemaker rate 5.7%, 87.6% had no paravalvular leak. The mild and moderate paravalvular leak was seen in 2.8% and 1.9%, respectively. The mean gradient decreased from 47.5 mmHg to 9 mmHg. The average ICU stay was 26.4 h, and the average hospital stay was 5.4 days. Our outcomes are comparable with the latest published low-risk trial. CONCLUSION: Minimalist, conscious sedation, transfemoral transcatheter aortic valve replacement when done following a standard protocol is safe and effective.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...